nūhou

Nūhou

XDB310 Pressure Sensor: Hoʻolālā a me nā ʻano ʻenehana o ka Diffused Silicon Pressure Transmitter

ʻO ke koʻikoʻi koʻikoʻi silikino

Hoʻohana ka XDB310 pressure sensor i ka diffused silicon pressure sensor core a hui pū ʻia me nā ʻāpana uila kiʻekiʻe ma o ke kaʻina hana koʻikoʻi.

Hoʻokumu ʻia ka mea hoʻouna kaomi

He ʻehā ʻāpana ka mea hoʻouna kaomi: ʻo ka mea ʻike kaomi (ʻike pū ʻia ʻo ka sensor kaomi), ke ana kaapuni, ka mea hoʻohui kaʻina, a me ka hale.

ʻO nā ʻāpana o waho o nā huahana P series e pili ana i nā mea hoʻohui wili, ka hale, ka mea ʻike puʻupuʻu (ka mea ʻike kaomi), ke ana kaapuni, a me nā uwea puka hōʻailona.

ʻO nā ʻāpana o waho o nā huahana P series e komo pū me nā mea hoʻopili hygienic clamp, hale, ʻeleʻele ʻike puʻupuʻu (ka mea ʻike kaomi), ana kaapuni, a me nā mea hoʻohui uila Hirschmann.

ʻO nā mea waho o nā huahana P series pū kekahi me nā mea hoʻohui pili, ka hale, ka mea ʻike puʻupuʻu (ka puʻupuʻu puʻupuʻu), ke ana kaapuni, a me nā mea hoʻohui hoʻohui mokulele M12X1.

ʻO nā hiʻohiʻona ʻenehana o ka Diffused Silicon Pressure Transmitter

ʻO ka hoʻonui ikaika a me ke kū'ē haʻalulu, me ka hiki ke hoʻonui i ka nui o ka laulā, a ʻaʻole hiki ke pohō maʻalahi ka mea ana.

ʻO ke kūpaʻa kiʻekiʻe, me ka liʻiliʻi o ka makahiki ma lalo o 0.1% piha piha, a ma o ka hoʻomaikaʻi ʻana i ka ʻoihana, ua hiki i nā hōʻailona ʻenehana paʻa i ke kiʻekiʻe o nā mea kani naʻauao.

ʻO ka pololei o ke ana kiʻekiʻe, me ka pololei ākea ākea a hiki i ka 0.5%, ʻo ia ka pōmaikaʻi nui ma mua o nā mea hoʻoili puʻupuʻu ceramic capacitance i ke ana ʻana i nā kaiapuni waena a me nā haʻahaʻa haʻahaʻa.

He liʻiliʻi loa ka drift helu ma ke ana ʻana i ka ʻenekini haʻahaʻa a me ka haʻahaʻa, akā ʻaʻole maikaʻi ka paʻa e like me ka ceramic capacitance pressure transmitters i nā kaiapuni kiʻekiʻe.ʻAʻole pono ka mahana wela ma mua o 85 degere, a pono ka mālama ʻana i ka hoʻoilo ke ʻoi aku ka mahana ma mua o 85 degere.

Ka laulā ana ākea, hiki ke ana mai -1Bar a 1000Bar.

ʻO ka liʻiliʻi liʻiliʻi, ka hoʻohana ākea, a me ka maʻalahi o ka hoʻokomo a me ka mālama.

Maikaʻi nā mea hoʻoheheʻe silicon diffused, me ka pōmaikaʻi nui i ke kumukūʻai transmitter i hoʻohālikelike ʻia i nā mea hoʻouna kaomi ceramic capacitance a me nā mea hoʻouna kaomi capacitance.

I ka hōʻuluʻulu manaʻo, hoʻohana ka XDB310 pressure sensor i kahi mea ʻike kiʻekiʻe kiʻekiʻe kiʻekiʻe a he ikaika ka overload a me ka haʻalulu, ke kūpaʻa kiʻekiʻe, a me ke ana kiʻekiʻe.Loaʻa iā ia ka laulā o nā noi a he kumu kūʻai.He mea kūpono ia no ka hoʻohana ʻana i nā wahi ʻokoʻa a me nā haʻahaʻa haʻahaʻa a he koho hilinaʻi no ke ana ʻana i ke kaomi ma nā ʻano ʻoihana like ʻole.


Ka manawa hoʻouna: Mei-05-2023

Waiho i kāu leka